牵牛钢材网资讯
    HGX22e/190-4S天行健直供原厂德国GEA BOCK5匹中高温船用压缩机
    发布者:txj52888  发布时间:2022-06-14 11:39:47  访问次数:590

    HGX22e/190-4S福州天行健17年专业直供原厂德国GEA BOCK船用压缩机及压缩机零部件

    原装德国Bizter船用压缩机及压缩机零部件

    德国原装Roller船用风机及风机零部件


    Semi-hermetic suction gas-cooled reciprocating compressor in compact design. The best possible serviceability is provided by means of a replaceable drive motor, among other things. The compressor stands out due to its outstanding running comfort and efficient operating performance. The suction shut-off valve can be rotated by 90° in each instance. Dependable mechanism lubrication is guaranteed by means of an oil pump which is independent of rotating direction, as well as a large-volume oil sump. An electronic motor protection uses PTC sensors in series to monitor the winding temperature and, if desired, the discharge gas temperature.
    Colour: blue (RAL 5000)


    Technical data

    HGX22e/190-4 S
    Application Refrigeration & AC
    Compressor refrigeration capacity 13.50 kW
    Power consumption 4.92 kW
    Current draw (400 V) 8.27 A
    Mass flow 0.127 kg/s

    at following operating condition:
    Refrigerant R404A, R507
    Reference temperature Dew point
    Evaporating temperature 5.0 °C
    Condensing temperature 50.0 °C
    Supply frequency 50 Hz
    Voltage 400 V
    Suction gas temperature 20 °C
    Subcooling (outside cond.) 0 K
    Number of cylinders / Bore / Stroke 2 / 55 mm / 40 mm
    Displacement 50/60 Hz (1450/1740 1/min) 16,50 / 19,80 m3/h
    Voltage 1) 220-240V Δ / 380-420V Y -3- 50Hz
    265-290V Δ / 440-480V Y -3- 60Hz
    Max. working current 2) 16.2 / 9.4 A
    Max. power consumption 2) 5.6 kW
    Starting current (rotor blocked) 2) 87.0 / 50.0 A
    Motor protection INT69 G
    Protection terminal box IP 66
    Weight 75 kg
    Frequency range 3) 30 -70 Hz
    Max. permissible overpressure (g) (LP/HP) 4) 19 / 28 bar
    Connection suction line SV 22 mm - 7/8 "
    Connection discharge line DV 16 mm - 5/8 "
    Lubrication Oil pump
    Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55
    Oil type R22 BOCKlub A46
    Oil charge 1,1 Ltr.
    Dimensions Length / Width / Height 468 / 240 / 315 mm
    Sound power level LWA 5) 70 db(A) @ -35/+40 °C
    69 db(A) @ -10/+45 °C
    67 db(A) @ +5/+50 °C
    Sound pressure level LpA 5) 58 db(A) @ -35/+40 °C
    57 db(A) @ -10/+45 °C
    55 db(A) @ +5/+50 °C

    Scope of supply

    Semi-hermetic two cylinder reciprocating compressor with drive motor
    Single-section compressor housing with hermetically integrated electric motor

    Winding protection with PTC resistor sensors and electronic trigger unit INT69 G
    115-230 V AC, 50/60 Hz, IP00

    Oil pump

    Possibility for connection of oil pressure safety switch MP55

    Possibility of connection of oil level controllers ESK, Traxoil, AC+R or CARLY 6)

    Oil charge:
    HG: BOCKlub A46
    HGX: BOCKlub E55

    Sight glass

    Suction and discharge line valve

    Inert gas charge

    Accessories

    Oil sump heater
    110-240 V - 1 - 50/60 Hz, 50-120 W, IP66
    PTC heater self-regulating

    USB converter for INT69 G Diagnose 7)

    Thermal protection thermostat per cylinder cover 8)

    Oil pressure safety switch MP55 230 V - 1 - 50/60 Hz, IP20 7)

    INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)

    DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 7)

    Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 7)

    Additional fan
    230 V AC - 1 - 50 Hz, 97 W, IP44
    230 V AC - 1 - 60 Hz, 128 W 7)

    4 anti-vibration pads enclosed

    Special voltage and/or frequency (on request)

    Notes
    1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request
    All data are based on voltage rms values
    2) - The stated value for the max. power consumption is valid for the adjusted power supply.
    - Starting current (rotor blocked):
    • Part winding (PW) motors: Winding 1 / Winding 1+2
    • Delta/Star (Δ/Y) motors: Δ / Y
    - Take account of the max. operating current / max. power consumption for designing motor contractors, feed lines, fuses and motor protection switches. Motor contractors: Consumption category AC3.
    3) The maximum permissible working current of the compressor (Imax) must not be exceeded. Take account of the guidelines for use of frequency inverter (see compressor assembly instruction or selection software).
    4) LP = Low pressure
    HP = High pressure
    5) Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.
    • A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement methods of the ISO 3740 standard with accuracy class 2 or higher were used .
    • A-weighted sound pressure level LpA (re 20 μPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.
    6) Only with additional adapter possible
    7) Enclosure
    8) Mounted