当前位置:首页 >> 产品展示 >> 仪器仪表 >> 自动化仪表 >>HONEYWELL温控器dc1040cr-30100b-e
HONEYWELL温控器dc1040cr-30100b-e放大图片

产品价格:1   元(人民币)
上架日期:2015年5月8日
产地:台湾
发货地:成都  (发货期:当天内发货)
供应数量:不限
最少起订:1台
浏览量:53
  暂无相关下载
其他资料下载:

         
成都鑫业达自动化成套设备有限公司

点击这里给我发消息
  详细说明  
品牌:霍尼韦尔产地:台湾
价格:1人民币/台规格:dc1040cr-30100b-e

简要说明:霍尼韦尔牌的HONEYWELL温控器dc1040cr-30100b-e产品:估价:1,规格:dc1040cr-30100b-e,产品系列编号:15882174796

详细介绍:

  

HONEYWELL温控器dc1040cr-30100b-e
联系人:魏工  电话:15882174684
            座机:028-84472033
              QQ:2030149354
产品资料:

terminals.

To withdraw the Digital Controller Programmer from its housing, simply grip the side 

edges of the front panel (there is a finger grip on each edge) and pull the panel

forwards. This will release the Digital Controller Programmer from its rear

connectors in the housing and will give access to the PCBs. Take note of the

orientation of the Digital Controller Programmer for subsequent replacement into

the housing.The positions of the PCBs are shown in Figure 3-1.

3-1

Figure 3-1 PCB Positions

3.2 REMOVING/REPLACING THE OUTPUT 2/OUTPUT 3

OPTION PCBs

With the Digital Controller Programmer removed from its housing:

1. Gently push the rear ends of the CPU PCB and Power Supply PCB apart

slightly, until the two tongues on each of the Output 2/Output 3 Option PCBs 

become dis-engaged - see Figure 3-2B; The Output 2 Option PCB tongues

engage in holes in the Power Supply PCB and the Output 3 Option PCB

tongues engage in holes on the CPU PCB.

2. Carefully pull the required Option PCB (Output 2 or Output 3) from its

connector (Output 2 Option PCB is connected to the CPU PCB and Output 3 

Option PCB is connected to the Power Supply PCB) - see Figure 3-2C. Note

the orientation of the PCB in preparation for its replacement.

Adjustments may now be made to the link jumpers on the CPU PCB, the Output

2/Output 3 Option PCBs (if DC output) and (if fitted) the DC Output 1 PCB. The

replacement procedure is a simple reversal of the removal procedure.

3.3 REMOVING/REPLACING THE RS485

COMMUNICATIONS OPTION PCB

The RS485 Communications Option PCB is mounted on the inner surface of the

Power Supply PCB and can be removed when the Digital Controller Programmer is 

removed from its housing (see Subsection 7.1) Figure 3-3 illustrates the

removal/replacement procedure. It is not necessary to remove the Output

2/Output 3 Option PCBs to perform this procedure.

3-3

Figure 3-3 Re mov ing the RS485 Communications Option PCB

3.4 INSTALLING/REMOVING THE DIGITAL INPUT OPTION

PCB

The location of the Digital Input Option PCB is shown in Figure 3-4. It is connected

to the CPU PCB via a flexi-strip connector, as shown.

To install the Digital Input Option PCB:

1. Hold the PCB ap proxi mately in po si tion and care fully in sert the free end

of the flexi- strip ca ble into the socket near the bot tom edge of the CPU PCB

(en sur ing that none of the pins on the end of the flexi- strip be come bent

and that the flexi- strip is not twisted).

2. Fully in sert the Digi tal In put Op tion PCB into its con nec tor at the rear of

the front panel (when the PCB is fully in serted, it will be come en gaged in

 


该公司其他信息