当前位置:首页 >> 产品展示 >> 仪器仪表 >> 温度仪表 >>台湾台仪温控器 TAIE FU72-101000代理商
台湾台仪温控器 TAIE FU72-101000代理商放大图片

产品价格:1   元(人民币)
上架日期:2015年5月28日
产地:台湾
发货地:成都  (发货期:当天内发货)
供应数量:不限
最少起订:1台
浏览量:107
  暂无相关下载
其他资料下载:

         
成都鑫业达自动化成套设备有限公司

点击这里给我发消息
  详细说明  
品牌:台仪产地:台湾
价格:1人民币/台规格:FU72-101000

简要说明:台仪牌的台湾台仪温控器 TAIE FU72-101000代理商产品:估价:1,规格:FU72-101000,产品系列编号:15882174684

详细介绍:

  

台湾台仪温控器 TAIE FU72-101000代理商
联系人:魏工  电话:15882174684
            座机:028-84472033
              QQ:2030149354
产品资料:

 

The software can communicate with the instrument via the RJ11 configuration socket located 

on the underside of the case, or via the Modbus TCP or RS485 communications options if 

either is fitted. Refer to the wiring section for connection details.

The configuration socket is intended for initial configuration of the instrument before installing 

in the application. An RS232 to TTL lead (available from your supplier) is required connect 

from the PCs RS232 serial port to this socket.

A front mounted USB port is available on some models; this can also be used to configure 

the instrument or transfer profile files, via a USB memory stick.

CAUTION:

The configuration lead/socket is not isolated from the process input or SSR Driver 

outputs. It is not intended for use in live applications.

89746546

A communications settings screen is shown whenever the user attempts to connect to the 

instrument from the software. The settings must be correct in order for communications to 

work successfully. First correctly select Configuration Socket or Bus as the Device connector, 

and select the PC Serial Com port that you have connected to

For Modbus TCP, select Ethernet (bus coupler).

If connecting via the configuration port, the Start 

and Stop bits must be 1 and Data bits 8. Parity 

must be None and address 1. The data bit-rate 

should be 4800 if Slot A is fitted with an Auxiliary 

input, 9600 if the Ethernet option is installed or 

19,200 for a Digital Input or if Slot A is empty.

If the instrument has an RS485 module fitted, the 

Address, Parity and Bit rate values must match 

those of the instrument (even if you are connecting 

via the configuration port). The Start and Stop bits 

must be 1 and Data bits 8.

USB Memory Stick Folders & Files

If a USB memory stick is to be used to transfer files between the instruments and/or the 

software, the files must be stored in specific DEVICE, CONFIG and PROFILE folders on the 

USB stick. When saving files from the software to the memory stick, ensure that you save 

them to the correct folder. Local storage on you PC can be in any folder of your choosing. 

The USB option also limits the file name to 8 characters plus the 3 digit . bct or .pfl extension. 

Longer file names will be truncated.

DEVICE – This folder must be located in the 

Root of the USB memory stick

CONFIG – Configuration files (*.bct)

PROFILE – Profile program files (*.pfl)

RECORDER – Recorder log folders/files. 

These can be created or saved from the PC 

software.

CAUTION:

When saving a file, the data will be overwritten If the file name already exists.

 


该公司其他信息
最新供求信息 企业产品推荐

暂无产品
  在线询盘/留言 请仔细填写准确及时的联系到你!  
您的姓名:
* 预计需求数量: *
联系手机:
*  移动电话或传真:
电子邮件:
* 所在单位:
咨询内容:
*
           您要求厂家给您提供:
  • 规格,型号
  • 价格及付款条件
  • 产品目录
  • 最低订货量
  • 运送资料
  • 提供样本
  • 库存情况
  • 包装材料