HA34e/215-4 HA3/235-4 HAX34P/215-4
HA34e/215-4 HA3/235-4 HAX34P/215-4
产品价格:¥12000(人民币)
  • 规格:HA34e/215-4 HA3/235-4 HAX34P/215-4
  • 发货地:福州
  • 品牌:
  • 最小起订量:1个
  • 诚信商家
    会员级别:钻石会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:福州天行健节能科技有限公司

    联系人:叶工(小姐)

    联系手机:

    固定电话:

    企业邮箱:2961668110@qq.com

    联系地址:福建省福州市鼓楼区水部街道六一中路71号皇岛中环F夹层T22单元

    邮编:350000

    联系我时,请说是在牵牛钢材网上看到的,谢谢!

    商品详情

      HA34e/215-4 HA3/235-4 HAX34P/215-4

      福州天行健provide原厂GEA-Bock船用压缩机及压缩机零部件

      福州天行健节能科技有限公司提供欧美日船舶原装进口品牌零部件



      HA single-stage compressors
      The HA-system - the best solution for deep-freezing!

      Special features:
      - Direct intake with external ventilation
      - Suction gas intake directly into the compressor
      - Motor cooled by an integrated ventilation unit

      This reduces the compressed gas temperature and thus expands the range of application while at the same time increasing capacity (deep-freeze, R22, R404A). At the same time, the compressor is physically separated from the compressor, with advantages particularly in the case of motor damage.


      HAX34e/215-4

      Application Refrigeration & AC

      Compressor refrigeration capacity 3.20 kW

      Power consumption 2.33 kW

      Current draw (400 V) 4.83 A

      Mass flow 0.024 kg/s

      at following operating condition:

      Refrigerant R404A, R507

      Reference temperature Dew point

      Evaporating temperature -35.0 °C

      Condensing temperature 40.0 °C

      Supply frequency 50 Hz

      Voltage 400 V

      Suction gas temperature 20 °C

      Subcooling (outside cond.) 0 K

      Number of cylinders / Bore / Stroke 4 / 41,5 mm / 40 mm

      Displacement 50/60 Hz (1450/1740 1/min) 18,80 / 22,60 m3/h

      Voltage 1) 220-240V Δ / 380-420V Y -3- 50Hz

      265-290V Δ / 440-480V Y -3- 60Hz

      Max. working current 2) 12.1 / 7.0 A

      Max. power consumption 2) 4.0 kW

      Starting current (rotor blocked) 2) 87.0 / 50.0 A

      Motor protection INT69 G

      Protection terminal box / HA-fan IP 66 / IP 44

      Voltage HA-fan 230 V - 1 - 50/60 Hz, 38 W

      Weight 94 kg

      Max. permissible overpressure (g) (LP/HP) 3) 19 / 28 bar

      Connection suction line SV 22 mm - 7/8 "

      Connection discharge line DV 16 mm - 5/8 "

      Lubrication Oil pump

      Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55

      Oil type R22 BOCKlub A46

      Oil charge 1,3 Ltr.

      Dimensions Length / Width / Height 578 / 303 / 318 mm

      Scope of supply

      Semi-hermetic four cylinder reciprocating compressor with drive motor

      Single-section compressor housing with hermetically integrated electric motor

      Oil pump

      Motor is cooled by an integrated ventilator with air deflection hood.

      230 V - 1 - 50/60 Hz, 38 W, 0,17 A

      Winding protection with PTC resistor sensors and electronic trigger unit INT69 G

      115-230 V AC, 50/60 Hz, IP00

      Possibility of connection of oil level controllers ESK, Traxoil, AC+R or CARLY 4)

      Oil charge:

      HA: BOCKlub A46

      HAX: BOCKlub E55

      Sight glass

      Suction and discharge line valve

      Inert gas charge

      4 anti-vibration pads enclosed

      Accessories

      Start unloader by means of a ESS (Electronic Soft Start), 400 V - 3 - 50/60 Hz, IP20 (Connection clamps IP00) for installation in switch cabinet

      Digital capacity regulator DCR14 230 V - 1 - 50/60 Hz, IP65

      1 digital capacity regulator = 50% residual capacity

      Cylinder cover prepared for digital capacity regulator

      Oil sump heater

      110-240 V - 1 - 50/60 Hz, 50-120 W, IP66

      PTC heater self-regulating

      USB converter for INT69 G Diagnose 5)

      Thermal protection thermostat per cylinder cover 6)

      Oil pressure safety switch MP55 230 V - 1 - 50/60 Hz, IP20 5)

      INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable)

      DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 5)

      Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 5)

      Step protection

      Special voltage and/or frequency (on request)

      Notes

      1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request

      All data are based on voltage rms values

      2) - The stated value for the max. power consumption is valid for the adjusted power supply.

      - Starting current (rotor blocked):

      Part winding (PW) motors: Winding 1 / Winding 1+2

      Delta/Star (Δ/Y) motors: Δ / Y

      - Take account of the max. operating current / max. power consumption for designing fuses, supply lines and safety devices. Fuse: Consumption category AC3.

      3) LP = Low pressure

      HP = High pressure

      4) Only with additional adapter possible

      5) Enclosure

      6) Mounted


    在线询盘/留言
  • 0571-87774297