      RHB-CAC1S2

      温度 ? 相对湿度测量仪器 ? 湿度发生器,露点仪,冷却镜面和校准 ? RHB-CAC1S Series
      压缩空气露点监控器

      2年保修CE
      NIST Traceable
      +/- 0.2 deg C
      Virtually Maintenance Free
      Easy to Install
      Self-Monitoring
      User-Programmable Audible and Visual Alarms and Relay Contact
      Programmable Automatic Balance Control (ABC)
      Widest Available Range of -60 to 50°C (-76 to 122°F)

      产品描述
      These compressed air dewpoint monitors have been designed to offer the highest level of reliability and accuracy available in such systems. They are fully NIST traceable and employ a chilledmirror sensor, the most accurate dewpoint sensing scheme available, to deliver consistent drift-free measurements without regular calibrations or sensor replacement.
      These compressed air monitors are complete dewpoint measuring systems. The ruggedized aluminum NEMA 12 (IP55) enclosure houses the sensor, control circuitry (including flow control) and is easily wall mounted to conserve space. Only the sample line and power connection are needed for the system to be operational.
      The monitors also offer a programmable automatic balance control (ABC) cycle that corrects for the light-reducing effects of mirror contaminates and allows for continuous monitoring and virtually maintenance-free operation.

      Specifications:
      DEW/FROST POINT RANGE
      Two-Stage (S2): -40 to 50°C (-40 to 122°F)
      Three-Stage (S3): -60 to 50°C (-76 to 122°F)
      Dew/Frost Point Accuracy: 0.20°C (±0.5°F)

      FUNCTIONALITY
      Power: 90 to 250 Vac, 50 to 400 Hz
      Operating Temperature: 0 to 50°C (32 to 122°F)
      Sample Connection: 1/4" compression fitting
      Sample Flow Rate: 0.5 to 5 SCFH; integral flowmeter
      Sample Pressure: 0 to 150 psig
      (higher pressures available, consult Engineering Department)
      Output: Analog: 4 to 20 mA (0 to 5 Vdc), 50 to 50°C (-58 to 122°F) or
      -75 to 75°C (-103 to 167°F)
      Compliance: 9.0 Vdc, 450 .
      Display: Red LED, 0.5" tall; 8-digit alphanumeric

      ALARM:
      Audible: >98 dba @ 2'
      Relay: 1 Form C, non-latching 10 A @ 240 Vac, 8 A @ 24 Vdc, 1/2 HP @ 240 Vac
      Visual: Flashing “ALARM” message

      产品编号  产品描述


      RHB-CAC1S2  Compressed air dewpoint monitor with 2-stage sensor
      RHB-CAC1S3  Compressed air dewpoint monitor with 3-stage chill mirror
       